ReChlorSystem

 

 

BROCHURE Download

 

Self  Cleaning Chlorination  Systems

 

 

CHLORINE GENERATORS FOR WATER DISINFECTION

Ozone Generator

Carbon Dioxide Systems

 

ReChlorSystem

 

Self cleaning pool chlorinators with inbuilt (pH, Redox, Tds, chlorine indirect readout) for residential swimming pools

Chlorine output from 40 to 160 grams per hour

 

MAIN FEATURES

 

1)    Inbuilt pH control  with peristaltic 4 lt./Hr. pump 

2)    Inbuilt Orp control and readout

3)    Salinity alarms

4)    Chlorine algorithm

5)    Chlorine output proportional (P.I.D.) from Redox readout

6)    Low acid level in the tank alarm

7)    Inbuilt Flow switch

8)    4-20 mA input for external analyzer

9)    Fully programmable software

 

CommChlorSystem

 

The Piscinadimare.it Chlorination Plant covers a diverse range of units, with sodium hypochlorite output varying from 40 grams to suit small commercial pools to the large production modules delivering 5 kilograms per hour. Unlike other hypochlorite generators, CLOROCELL system does not need any hypochlorite solution intermediate storage: the produced hypochlorite solution is dosed in the process on a continuous basis and rate of production is directly controlled according to instantaneous process needs.
Not having any intermediate storage tank allows to avoid the problem of H2 developing from solution into tank, (and related problems of explosion when this gas is present in specific percentage in air).
Moreover there is no possibility of hypochlorite solution decay due to storage, that may lead to loss of oxidising power and to presence of undesired substances in solution.
Process control carried out on a continuous basis allows to produce only the hypochlorite quantity instantaneously required by the process, so avoiding too high dosages that lead to increase of costs and to the need to remove the excess of chlorine before discharging the water.

ControlSystems

The quality of the water from a health, aesthetic, and safety point of view is the main characteristic in dealing with swimming pools. Piscinadimare.it has made automatic systems for all needs and applications -

private, semi-public, and public swimming pools. The automatic systems make it possible to analyse the water and to suitably pilot dosing units to maintain optimum water quality.

 

. instruments for the measure of chlorine, pH , temperature and salinity

. PLC (man/machine interface) touch-screen (optional) display for electrochemical measures and control of chlorine, temperature, acid (pH) and salinity.

Graphic display of the historical trend of previous days, RS485 serial output, MODBUS communication.

 

 

OzoneSystem

PISCINADIMARE.IT  produces a corona-discharge ozone generator  for swimming pools with a 18 grams/hour of ozone from air production.

 

MAIN FEATURES

 

1) Oxigen separator

2) Corona discharge generator

3) Injection system

4) Contact chamber

5) Redox control

 

 

Download

Carbon dioxide

Download

Benefits of carbon dioxide in swimming pools

CO2System

The ECO2 control unit operates at a low pressure (2 bars) and come complete with a feed supply adjustable regulator and gauges. Mount the system securely to a standard high pressure Carbon Dioxide cylinder. PVC injector check valve chamber should be plumbed into the return line in appropriate location as determined by installer and connected to the system with 3/8" flexible tubing included.
Operation and Maintenance
The flow rate has been preset to meet maximum demand for CO2 pH control. The controller shall actuate the flow control solenoid valve to provide pH correction as determined by our factory preset proportional feed control logic. Maintenance of the flow control unit is minimal, normal care in cleaning is advised. Field information and research indicates that it is impossible to achieve a pH value below 6.7.